- Description
-
This CA SOLVE:Operations Automation health check checks that the SOLVE SSI SSID is defined and connected. The check runs every 15 minutes.
- Best Practice
-
Ensure that the following conditions are met:
- The SOLVE SSI started task is active.
- The SOLVE SSI SSID value for the region matches the SSID= parameter for the SOLVE SSI started task.
- The SOLVE SSI SSID and the AOM SSID are different.
- Parameters Accepted
-
None.
- Debug Support
-
No.
- Verbose Support
-
No.
- Reference
-
None.
- Non-exception Messages
-
The following messages can appear in health checker:
- SOLVE SSI SSID correctly defined and connected. SSID is ssidname.
- The region is initializing. Check is not relevant at this time.
- The region is shutting down. Check is not relevant at this time.
- Exception Messages
-
If an exception occurs, the following messages are issued as WTOs and written to the SYSLOG:
- CAH0001E The check timed out while waiting for a response to a command.
- NMH0108E SSID error, no SSID specified.
- NMH0108E SSID error, ssidname is not connected.
- NMH0108E SSID error, SSID matches AOM SSID(ssidname).