Use the AOF production compiled rules library to store compiled versions of your production rules. With OPSVIEW option 4.5.2, you can list and manipulate the rules in this library.
Note: Before you can access the AOF Compiled Rule Set List panel, you must allocate a data set for your compiled rules output. Allocate the data sets by setting the AOFPRECOMPILED and AOFPRECOMPILEDDSN parameters.
The data set must be a partitioned data set with these attributes:
|
Attribute |
Value |
|---|---|
|
RECFM |
Fixed block (mandatory) |
|
LRECL |
4096 (mandatory) |
|
BLKSIZE |
4096 or greater (must be a multiple of 4096) |
|
DIRECTORY BLOCKS |
User-defined (dependent on number of rules) |
|
SPACE |
User-defined (dependent on number of rules) |