Following is an example of the first screen of the OPSVIEW Address Space Control Panel:
Address Space Control --- XE61 --- O P S V I E W ---------------- ROW 1 OF 192 Command ===> Scroll ===> CSR Line Cmds: S Sec browse, C Cancel, D Cancel w/dump, Q Quiesce, R Resume - Job Name- St ASID Typ DPrty SrvClass Prd Aff -- CPU -- Elapsed SwapRsn -> *MASTER* NSW 0001 SYS (FF)255 SYSTEM 001 NONE 246.435S 33.55.20 ACF2 NSW 0018 STC (FE)254 SYSSTC 001 NONE 012.461S 33.55.12 ALLOCAS NSW 0012 SYS (FF)255 SYSTEM 001 NONE 000.059S 33.55.20 ANDOL01 OWT 009C TSU (FF)255 TSO 001 NONE 001.820S 01.45.18 TERM INPUT ANTAS000 NSW 000D SYS (FB)251 STCPROD 001 NONE 000.053S 33.55.11 ANTMAIN NSW 000C SYS (FF)255 SYSTEM 001 NONE 002.296S 33.55.17 APPC NSW 0073 STC (FE)254 SYSSTC 001 NONE 000.156S 33.52.04 AREAS01 IN 009E TSU (FB)251 TSO 001 NONE 016.693S 03.05.31 ASCH NSW 0075 STC (FE)254 SYSSTC 001 NONE 001.777S 33.52.04 ASCHINT OWT 0085 INI (FF)255 SYSSTC 001 NONE 000.001S NOTAVAIL DETECTED ASCHINT OWT 0083 INI (FF)255 SYSSTC 001 NONE 000.001S NOTAVAIL DETECTED ASCHINT OWT 0081 INI (FF)255 SYSSTC 001 NONE 000.001S NOTAVAIL DETECTED ASCHINT OWT 0084 INI (FF)255 SYSSTC 001 NONE 000.001S NOTAVAIL DETECTED ASCHINT OWT 0086 INI (FF)255 SYSSTC 001 NONE 000.001S NOTAVAIL DETECTED ASCHINT OWT 0082 INI (FF)255 SYSSTC 001 NONE 000.001S NOTAVAIL DETECTED ASTEX NSW 0076 STC (FB)251 STCPROD 001 NONE 425.674S 33.52.03 BLAMI02 OWT 00B8 TSU (FF)255 TSO 001 NONE 001.042S 00.44.00 TERM INPUT BPXOINIT OWT 001A SYS (FF)255 SYSTEM 001 NONE 001.584S 33.53.15 DETECTED CALDAP OWT 008A STC (FF)255 STCTEST 001 NONE 000.021S 33.51.56 DETECTED CALDAP2 OWT 0069 JOB (FF)255 OMVS 002 NONE 000.109S 33.51.56 DETECTED
You see these fields when you first enter the Address Space Control panel and when you scroll to the leftmost view. The fields of data that appear on the first (leftmost) view of the Address Space Control panel are:
The TSO user ID, batch job name, or started task name of the resource that is running in the address space.
The status of the address space. Values are:
The ID number of the address space.
The type of the address space. Types are:
The dispatching priorities of the address spaces in both decimal and hexadecimal (in parentheses) format.
WLM service class. When the system is in Compatibility mode, this field is blank and cannot be modified. When the system is in Goal mode, the value of the SrvClass field is the only value on the Address Space Control panel that can be modified. To modify this value, overtype this field with a valid WLM service class name. CA OPS/MVS internally invokes the OPSCMD command processor to issue a z/OS RESET command. Since the CA OPS/MVS security mechanism controls the OPSCMD command processor, you can use a security rule to restrict its use. You must have the authority to issue a z/OS RESET command.
WLM (Goal mode) or SRM (Compatibility mode) service period number for the address space.
The processor affinity. This value is either NONE, which indicates that there is no additional processor involvement, or a four-character system ID.
The elapsed CPU time used by this address space. If the value contains a suffix of S, the value indicates the number of seconds used. If the total CPU time used by the address space is greater than 60 seconds, the value appears in HH:MM:SS format.
The total time that has elapsed since the address space was started.
The reason an address space has been swapped out. Values are:
| Copyright © 2012 CA. All rights reserved. | Tell Technical Publications how we can improve this information |