Previous Topic: Display Channel Paths (Option 3.5.3)

Next Topic: Display Devices on a Local System (Option 3.5.5)

Display Systems Attached to a Control Unit (Option 3.5.4)

The control unit display panel displays control unit connection information. This panel lets you limit the display to control units for a specific device.

To identify z/OS systems attached to a control unit

  1. From the Switch Operations Facility Menu, choose option 4: Control Units - View control units.

    The following menu displays:

    SOF --------------------- O P S V I E W ------------------- Row 1 to 11 of 66 Wait ===> 60 VIEW Control Units on All Systems Server: A11SENF | Control Unit Identification | Connected | Sel Type Mod Mfg Serial Num Tag Sys Swi Dev ___ _____ ___ ___ ____________ ____ ____ ____ _____ I= CXX000 000 CSC 000000000000 0000 1 1 2 CONTRX 000 EMC CLX060051896 0000 1 1 1 002064 000 IBM EB11B0047204 0000 1 1 16 002064 000 IBM E811B0047204 0000 1 1 16 002064 000 IBM 000000047204 0000 1 2 144 002074 000 BTI 000A03093858 0000 1 1 1 002074 000 BTI 000E36000320 0000 0 1 0 002094 000 IBM AF11A0050851 0000 1 1 16 002094 000 IBM 0000000ACAAE 0000 1 1 1 002094 000 IBM 000000050851 0000 1 5 412 002105 000 EMC 000000020720 0000 1 3 4784 Command ===> Scroll ===> CSR

  2. On the selection line, define the display criteria to limit the information and press enter.

    The panel displays only the requested information.

  3. Enter line commands to display additional panels.

    Additional panels are displayed that let you do the following: