Use the following line commands on the Rule Set List panel. Issue line commands in the prefix area preceding the name of the desired rule set.
Sets the auto-enable flag for each rule in the rule set to Y. This means that when the rule set is enabled, all the rules in it are automatically enabled.
Compiles all of the rules in the set into the compiled rule data set.
Disables all of the rules in the rule set that were previously enabled.
Enables all of the rules in the rule set that have values of Y in their AE fields. You enable a rule so that it can be tested. If a rule contains syntax errors, the E command fails.
Selects the rule set to be displayed. When you enter the S command, the Rule List panel appears. The Rule List panel lists all of the rules in the rule set you selected. For details, see The Rule List Panel in this chapter.
Accesses the PDS member list display for the rule set. This display is identical to the member list display you see when you choose ISPF/PDF option 3.1 (Library Utility).
Deletes all of the rules in the set from the compiled rule data set.
For all rules in the rule set, resets the value of the AE field to N. This means that all rules in the rule set are ineligible to be enabled.
Point-and-shoot is enabled to issue the S line command for any displayed Rule set. To issue the S line command for a displayed Rule Set using the point-and-shoot method, place the cursor to the left of the Rule Set and press Enter. Point-and-shoot is enabled only if no primary or line commands have been entered.