OPSVIEW Control Option › How to Copy an Existing CICS Connection › Define a New CICS Connection
Define a New CICS Connection
Follow these steps to define one or more CICS connections:
- In the CICS Jobname field, modify the job name as required.
- If multiple CICS regions have the same job name, specify a step name in the Stepname field to distinguish this CICS connection from other CICS connections. In such cases, the value of the Stepname field should be the task ID (for example, S CICSMVS.TOR). Each CICS connection must have a unique jobname or jobname.stepname. No duplicates are allowed. In the fields on the remainder of the panel, add or modify up to 100 CICS transient data queue names for CA OPS/MVS to intercept and send to the AOF for processing.
Note: Transient data queue destination names are not required, but an empty list results in no messages being processed by the AOF. You can use the special destination name, which is %%%%, to refer to the list of destination names in the DEFAULT connection definition (if the DEFAULT connection definition exists).
- Press Enter to define the definition.
- When finished, press End.
Your CICS connection definition session is terminated and you are returned to the COF CICS Connection Display panel.