Previous Topic: Migrate from r11.7 to r11.8

Next Topic: OPSLOG WebView Client Connection to OPSLOG WebView Server

Update Rules and Execs for OPSDEV Function Changes

The CA OPS/MVS OPSDEV function has been updated with additional device statuses returned in Word 3 and Word 14. This function includes a new U status for returning devices with a status of unavailable. If your automation rules or execs use the OPSDEV function and query status information in either Word 3 or Word 14, you may need to update your rules, execs, or both.

To update your automation for OPSDEV changes

  1. Search for occurrences of OPSDEV in your rules and execs to determine whether any of those rules and execs are using the OPSDEV function and are examining the returned contents of either Word 3 or Word 14.
  2. If a rule or exec is examining the returned values in Word 3, add to the rule or exec the new UNAVAIL status value as necessary.

    Example: If you examine Word 3 to find all OFFLINE devices, you will need to update your rule or exec to look for a value of UNAVAIL as well as a value of OFFLINE. Or, you can use the F status on the OPSDEV function call to filter the devices returned to OFFLINE devices only, which will also include UNAVAILABLE devices.

    Note: The UNAVAILABLE tape device status was introduced at z/OS 1.10 and is currently only valid for tape devices. Therefore, Word 3 will only contain the UNAVAIL value on systems running z/OS 1.10 or higher as no tape device can be in UNAVAILABLE status unless the system is running at least z/OS 1.10.

  3. If a rule or exec is examining the returned values in Word 14, add to the rule or exec the new AFH (auto-switch devices assigned to a foreign host) status value as necessary.

    Example: If you are examining Word 14 to find all auto-switch devices, you will need to update your rule or exec to look for a status value of AFH as well as a status value of AUTS.