Type E (MNPS Application Recovery) Entry

Type E entries for MNPS application records are described in the following table. These entries contain 32 bytes.

Length

Offset

Type

Description

8

0

C

Application program name

4

8

N

Number of sessions recovered successfully by this VTAM

4

12

N

Number of session recoveries attempted

4

16

N

Number of HPR pipes recovered successfully by this VTAM

4

20

N

Number of HPR pipes recoveries attempted

8

24

N

Total recovery time spent recovering sessions (TOD clock format)


Copyright © 2010 CA. All rights reserved.