Previous Topic: Internal Error Messages

Next Topic: CICS Messages

Client Messages

Client (TSO ISPF dialog) messages initially display a short message text. Press PF1 for an extended explanation of the message. Client messages are listed in the table that follows with the short and extended message text.

If a problem persists, contact Customer Support with the full message text and information about the circumstances when the error occurred.

Message Number

Message Text

Extended Explanation

TNM001

Invalid primary command

Valid primary commands are shown at the top of the panel.

TNM002

Parameter missing

Specify ON or OFF as a parameter for this command.

TNM003

Missing valid Jobname

A valid jobname must be specified.

TNM004

Incorrect format

Jobname must be 1-8 characters and start with an alpha or a national character.

TNM005

Invalid data set name

A valid data set name must be specified.

TNM006

Monitor started/queued

Monitoring has been started or queued for &jobn.

TNM007

Must specify an interval

A valid interval must be specified.

TNM008

CSECT mode required

Issue the MOde Csect command and retry.

TNM009

&ZCMD not valid

To cancel changes type END; to save changes, clear command line, press Enter.

TNM009A

Duration not valid

The monitor duration must be a number between 10 and 99999 or STEP.

TNM009B

Mode missing or invalid

Mode must be Csect, Module, Pseudo or 4GL

TNM009C

Invalid name

Enter up to 8 alphanumeric characters (first must be alphabetic or national).

TNM009D

Invalid pattern

Enter up to 8 alphanumeric or pattern characters.

TNM009E

Invalid monitor dsn

Monitor data set name is invalid. Either one of the variables specified is not defined, the length of a data set name qualifier is invalid, or the data set name contains invalid characters.

TNM009F

Invalid duration

Monitor duration is invalid. It must be a whole number from 1 to 99999 or must be a whole number from 1 to 9999 with either an S or M appended to the number to indicate seconds or minutes, respectively.

TNM009G

Invalid sample count

Number of samples is invalid. Must be a whole number from 10 to 999999.

TNM009H

No monitors in group

No Monitors have been defined to the group. Please use the ADD command to associate monitors with this group.

TNM009I

Monitor profile missing

A monitor associated with this group could not be found. Please either remove the monitor from the group or redefine the new monitor.

TNM009J

No trigger assigned

The monitor group requires a monitor to be assigned as the trigger. Please use the T line command to assign a monitor as the trigger.

TNM009K

Duplicate group found

Another group by the name of &group has already been defined. Please respecify a new group name.

TNM009L

Profile already in group

One or more profiles you have selected are already in the group.

TNM009M

Invalid numeric

Number is invalid. Please correct and press Enter.

TNM009N

Invalid monitor time

Invalid monitor time duration. Monitor time must be a numeric value from 1 to 9999 (166 minutes). The number can be appended with either a M for minutes or S for seconds. No suffix defaults to seconds.

Example: 120S would be a duration of 2 minutes. Likewise, 2M would indicate 2 minutes as well.

TNM009O

Statistics unavailable

Data set or volume performance information is not available. Performance sections will not be displayed.

TNM009P

&nametype name truncated

The &nametype name can not be greater than eight characters. The specified name will be truncated.

TNM009Q

&node invalid

&node is not a valid variable for the monitor data set name.

Valid variables are: &&USERID, &&PREFIX, &&PROFILE, &&PGMNAME, &&SYSDATE, &&SYSTIME, &&SYSNAME, &&JOBNAME, &&STEPNAME, &&PROCSTEP, &&DSNPRFX, and &&JOBID.

TNM009R

Invalid date range

The specified date range has passed. The monitor will not start.

TNM009S

Group &group missing

The entry for &group can not be found. You will need to redefine the Group Definition to continue.

TNM009T

Valid for USS/JVM only

The Long Name command is only valid for USS or JAVA short names (module name entry contains a dash -).

TNM009U

Step is missing

Step name is required when Procstep name is specified.

TNM009V

No Process info

There is no detail or statistical information available for the selected Process ID.

TNM009W

&node invalid

&node is not a valid node for the monitor data set name. The node must be eight characters or less.

TNM009X

Mode missing or invalid

Mode must be Current, Via, or Application.

TNM009Y

Mode missing or invalid

Mode must be Task or Module.

TNM011

Module missing

A module identifier must be specified.

TNM012

Csect missing

A Csect identifier must be specified.

TNM013

Description missing

A description must be specified.

TNM014

Return Code=&RETCD

The function returned with the indicated return code.

TNM015

Analyzing data

N/A

TNM016

Listing unavailable

Enable dynamic registration using the Profile Parameters panel, or use manual registration to make a listing data set available.

TNM016B

Stacked Statement

The program statement (&STMT) is included in statement &ACTSTMT in the program listing. Statement &STMT is the &IDXMSG statement.

TNM017

Invalid line command

Valid commands are listed at the top of the panel.

TNM018

Detail data unavailable

No detail data monitored for this condition.

TNM019

Pseudo group missing

A pseudo group must be specified.

TNM019A

CSECT not provided

This Histogram contains information for a Module without a Csect. Statement numbers are not available, even if the program is registered.

TNM019B

Delay data unavailable

No delay is available for this target.

TNM019C

Duplicate entry

&modp already exists. Choose another Module prefix.

TNM019D

Task(s)/Tran(s) tagged

The task or transaction was previously selected; the Select command is ignored. Use RECall to restore all task/tran data.

TNM019E

Only 1000 Tags permitted

Only 1000 tasks/trans may be tagged

TNM019F

No 4GL info available

CodeView will display in CSECT mode.

TNM019G

No more detail

There are no more levels of detail to report for this function.

TNM020

Invalid mode

The Delays line command requires CSECT or MODULE display mode.

TNM021

Report printed

A report of the analysis results shown has been sent to SYSOUT.

TNM022

Already defined

A profile with the name you specified already exists as a monitor set.

TNM023

Profile name required

The name of a profile must be specified when using ADD.

TNM024

Profile name required

The name of a profile must be specified when using the SAVE command.

TNM025

Specifications saved

The current specifications have been saved under the given profile name.

TNM026

Profile not found

A profile with the indicated name does not exist as a monitor specification.

TNM027

Too many selections

Only one profile may be selected.

TNM028

Profile retrieved

The desired profile has been read.

TNM029

Not a proper listing

The specified member does not contain a proper compile listing.

TNM030

Registration error

Check format of listing dsn and compile options.

TNM030B

&Csect not in &MODULE

The Csect was not found in the load module listing.

TNM031

Successfully completed

The listing was successfully registered.

'&REGMSG1

'&REGMSG2

'&REGMSG3

TNM032

Invalid numeric

Specify a valid integer number instruction size.

TNM033

Unable to start monitor

Server space &TUNSSID not found.

TNM034

Request is waiting

The monitor request is queued in the server space for execution.

TNM035

Request is active

CA MAT is currently monitoring the desired target.

TNM036

Request complete

The request is no longer tracked in CA MAT. The output data set is available.

TNM037

Request incomplete

The request is no longer tracked in CA MAT. No data is available.

TNM038

CA MAT inactive - Data

CA Mainframe Application Tuner is not active but the output data set is available.

TNM039

Member not found

The specified member cannot be found in the data set.

TNM040

Data loaded

The monitoring data has been successfully loaded into your environment.

TNM041

Registering: &csect

N/A

TNM042

Monitor data set empty

The input data set does not contain any samples.

TNM042A

Sample count is low

The input data set contains &samples meaningful samples, which may not be enough to be statistically valid.

TNM043

Invalid line command

The only allowable command is (S)elect.

TNM044

Statements: &STMT

N/A

TNM044A

Scanned lines: &PLINES

N/A

TNM045

Samples (&NORMLIZE): &TOTSAMP

N/A

TNM046

Invalid primary command

Valid primary commands are listed at the top of the panel.

TNM047

Field must be specified

This entry should not be left blank.

TNM048

Field contents invalid

A positive numeric integer must be specified.

TNM049

Profile saved

Your profile information has been saved.

TNM049A

Listing(s) registered

The selected listings have been re-registered.

TNM049B

Registered with Offsets

Selected listing has been re-registered but using the offset table, not the object listing. Imbedded PROC displacements could be incorrect.

TNM050

Invalid primary command

Valid primary commands are listed at the top of the panel.

TNM051

Unable to allocate

CA MAT was unable to allocate the sysout data set. Check profile.

TNM052

Data not loaded

The indicated profile data has not been loaded yet. Use L line command.

TNM053

Unable to Start

This monitor request has the same profile name as another from the same user.

TNM054

Unable to Start

This monitor request uses the same data set as another monitor request.

TNM055

Monitor stopped

This monitor request has been stopped.

TNM056

Monitor not stopped

This monitor requested was not found.

TNM057

Monitor not stopped

This server space was not found.

TNM058

Invalid histogram target

A histogram can not be produced for a pseudo entity.

TNM058A

Invalid histogram target

No Active samples for this Module/Csect. Use Analyze All option.

TNM058B

Invalid histogram target

No Active samples for Module: &MODULE Csect: &CSEX - Use Analyze All option.

TNM059

Data set not found

The monitor data set must exist before the profile can be saved.

TNM060

Invalid numeric

This input field requires the specification of an integer.

TNM060A

Invalid time specified

This field requires a time in the format HHMM.

TNM060B

Ending time incorrect

The ending time must be greater than the starting time.

TNM060C

SYSOUT class incorrect

SYSOUT class must be A through Z or 0 through 9.

TNM060D

Group invalid

Instruction group must be a numeric value or STMT.

TNM061

Allocation failed

The monitor data set did not exist and cannot be allocated.

TNM062

Field contents invalid

This field can only contain ON or OFF.

TNM062A

Field contents invalid

This field can only contain PSEUDO, MODULE, CSECT, 4GL.

TNM063

Help &SUBTOPIC not found

Help topic &SUBTOPIC in member &TOPIC could not be found in library TUNHELP.

TNM064

Invalid primary command

Help does not process any special primary commands.

TNM065

Missing field

This field must be non-blank.

TNM066

Program missing

Program name must be specified.

TNM067

Invalid info target

Cannot display load module info for pseudo name.

TNM068

No info available

There is no load module information available for &MODNM.

TNM069

Inconsistent data

Blank out one of the numeric fields to correct.

TNM070

Already active

CA MAT is already active on another split of ISPF.

TNM071

Corrupted sample set

Possible abend x37 on monitor data set. Check server space log.

TNM072

Still active/waiting

Monitor still active or waiting to sample target.

TNM072A

Using previous data

Still active/waiting - analysis will use previous monitor data.

TNM073

Invalid data set name

The name you have entered is not a valid data set name.

TNM074

Access denied

You are not authorized to monitor this job.

TNM074A

Access denied

You are not authorized to access this monitor data set.

TNM074B

Access denied

You are not authorized to cancel this profile.

TNM075

Server space not found

The server space is not started.

TNM076

Data set not found

&msgdsn

TNM077

Incomplete Monitor Data

Analysis results are likely to be incorrect. The most likely reason is insufficient monitor data set size. Please increase the size and reinvoke the monitor. For additional information, check the server job log.

TNM078

Press PF3 for options

This is a high level breakdown by task. Continue by pressing PF3.

TNM079

???

Use Option 1 to define or start a monitor and to analyze the results.

TNM079A

Data set migrated

&msgdsn

TNM080

Select required

Use Select line command to indicate which profile to duplicate.

TNM081

Unable to Start

The maximum number of concurrent monitors would be exceeded. Try later.

TNM082

@DAM not found

The Dynamic Area Manager component cannot be loaded.

TNM083

Release mismatch

The TSO client and the server space components are at different release levels; enter HELP for more information.

TNM084

Conversion complete

All data converted into current release format.

TNM085

&badrec record errors

&badrec records from the input data set have logic errors.

TNM086

Error retrieving listing

&dsn could not be found.

TNM087

Error opening table

CA MAT listing table &cset was not available.

TNM088

Member not found

Member or data set not found for listing.

TNM089

No detail information

There is no detail information available for the selected location.

TNM089A

No Data Found

No DB2 data for the selected item was found.

TNM089B

Unable to open TUNLLIB

TUNLLIB cannot be opened - analysis cannot be done.

TNM089C

Insufficient storage

Unable to obtain enough virtual storage. Analysis cannot be done.

TNM089D

ESTAEX entered

ESTAEX entered and processed - abend occurred during data processing.

TNM089E

Driver error detected

Data processing error detected.

TNM089F

Non-cursor DB2 request

The DB2 UPDATE or DELETE request is not a non-cursor request. No DELCARE statement is relevant.

TNM089G

Not valid for DECLARE

No DECLARE can be associated with the selected DB2 statement. DECLAREs can only be associated with OPEN, CLOSE, UPDATE, DELETE and FETCH DB2 commands.

TNM089H

EXPLAIN is from DECLARE

EXPLAIN data being shown is from the DECLARE CURSOR statement number.

TNM089I

No DB2 Data was sampled

There was no DB2 data sampled during this monitor.

TNM089J

No samples were taken

There were no samples taken while this SQL statement was executing. The data presented is from the DB2 intercept.

TNM089K

No SQL data was found

Ensure that the DB2 plan was bound correctly. Static and dynamic SQL are captured by the DB2 sampler. Static SQL is also obtained from the DB2 catalog. DB2NOCAT=YES will suppress DB2 catalog access. SQL is captured from the DB2 intercept depending on the settings for DB2HVSQL and DB2HVDYN. DB2HVDYN=YES will intercept only dynamic SQL statements. DB2HVSQL=YES will intercept all SQL statements. The flag settings for this run can be viewed in option 0 OverView.

TNM089L

No intercept data found

There is no data available from the DB2 intercept. The data presented is from sample data only.

TNM090

Field contents invalid

This field can only contain Y or N.

TNM090A

Field contents invalid

This field can only contain Y, N, U, or ALL.

TNM090B

Field contents invalid

This field can only be Y if USE PROTSYM is also Y. Otherwise it must be N.

TNM090C

Field contents invalid

Specify a number from 1 to 8, which must correspond to the data set list below. Enter zero if no data set names are specified in the list.

TNM090D

Field contents invalid

PROTSYM data set name must be specified to be the Endevor DSS .PROTSYM.

TNM091

Job submitted

Your batch request has been submitted.

TNM092

Invalid jobname

The jobname must follow the rules for jobnames: from one to eight alphanumeric and/or national characters
(A-Z, 0-9, #, $, @).

The first character must be alphabetic or national (A-Z, #, $, @).

TNM093

Invalid DSORG

The monitor data set does not have a proper data set organization.

TNM094

Invalid profile name

The profile name must follow the rules for job/member names: from one to eight alphanumeric and/or national characters
(A-Z, 0-9, #, $, @).

The first character must be alphabetic or national (A-Z, #, $, @).

TNM095

Missing profile name

The profile name is required.

TNM095A

Missing data set name

The data set name is required.

TNM096

Invalid job/profile name

The job/profile name must follow the rules for job/member names: from one to eight alphanumeric and/or national characters (A-Z, 0-9, #, $, @).

The first character must be alphabetic or national (A-Z, #, $, @).

TNM097

Invalid mode

Mode must be CSECT or MODULE.

TNM098

Invalid class

Only the characters A-Z, 0-9 and * are acceptable.

TNM099

No data available

There is no data available for the requested function.

TNM100

Missing table entry

Processor for CICS &tabtype statistics table is missing.

TNM100A

Transaction not found

CICS transaction &stattran not found.

TNM100B

Invalid request

Function is unsupported for this CICS release. This is a non-CICS transaction.

TNM100C

Statistics not available

Summary statistics have not yet been collected.

TNM100D

Error creating table

User-defined warning criteria will not be available. Error for &ErrType.

TNM100E

Warning table error

Missing entry in warning table - notify Customer Support (&wrnfld).

TNM100F

Invalid operator

Cond value must be GT, GTE, LT, LTE, EQ, NE or OFF. You coded &WrnCond.

TNM100G

Value not numeric

Threshold value must be numeric. You coded &WrnVal.

TNM100H

Invalid value

Signed threshold values not allowed. You coded &WrnVal.

TNM100I

Invalid condition

Threshold condition LT 0 or LTE 0 is invalid. You coded &WrnCond &WrnVal.

TNM100J

Warning Table created

Table of summary statistics warning thresholds was created successfully.

TNM100K

Warning Table created

Table of transaction statistics warning thresholds was created successfully.

TNM100L

Error creating table

Bad word count. User-defined warning criteria will not be available.

TNM100M

Invalid value

Time fields must have format hh:mm:ss.ttttt. You coded &WrnVal.

TNM100N

Invalid condition

Threshold condition LT 00:00:00.00000 or LTE 00:00:00.00000 is invalid. You coded &WrnCond &WrnVal.

TNM100P

Invalid name

&ttran is not a valid CICS transaction name.

TNM110

No rows

Monitor file is empty. RC = &msgrc.

TNM111

No data

System error - address data not found. Contact Customer Support.

TNM11A

Pageout error

Pageout error for &mydsn. Contact Customer Support.

TNM112

Context changed

Context changed to &NORMLIZE.

TNM113

Invalid fields

System error - invalid field list. Contact Customer Support.

TNM114

Invalid table

System error - TUNOUT table empty. Contact Customer Support.

TNM115

Not enough stg

There might not be enough >16M storage to perform the requested function.

TNM116

Invalid field

System error - invalid field name &BADFLD. Contact Customer Support.

TNM117

Open error

Open error for History file. Contact Customer Support.

TNM118

File error

Monitor file not found. Contact Customer Support.

TNM119

ALLOC error

ALLOC error for &mydsn. Contact Customer Support.

TNM120

Not enough memory

There is not enough >16M storage to process the current monitor file for this function.

TNM121

Paging is &TUNOUTP

TUNOUT paging is &TUNOUTP.

TUNM000A

INVALID OPTION

Invalid choice, please select one of the options listed.

TUNM000B

INVALID COMMAND

Command &ZCMD is invalid. Please press HELP for a list of commands.

TUNM000C

INVALID SELECTION

Selection is either not in list or not entered if required.

TUNM000D

INVALID VALUE

Please enter one of the listed values.

TUNM000E

FIELD NOT MODIFIABLE

Include, Exclude, and Move are not supported for this field. Request ignored.

TUNM000F

REPORT GENERATED

Report generate and written to SYSOUT.

TUNM000G

REPORT CANCELLED

Report generation is cancelled at the user’s request.

TUNM000H

NO FIELD LEVEL HELP

No specific help was defined for this field.

TUNM000I

EXCLUDE SYNTAX ERROR

Syntax error on EXCLUDE command. Please press HELP for more information.

TUNM000J

FIELD NOT FOUND

Field entered is not found. Request ignored.

TUNM000K

FIELD FIXED

Field is fixed and cannot be modified. Request ignored.

TUNM000L

ALREADY EXCLUDED

Field is already excluded. Request ignored.

TUNM000M

ALREADY INCLUDED

Field is already included. Request ignored.

TUNM000R

TABLE IS EMPTY

No rows in table to export. Request ignored.

TUNM000S

SORT NOT SUPPORTED

The SORT command is not supported for this screen. Request ignored.

TUNM000Z

COMMAND CONFLICT

Line command(s) entered are incomplete or contradictory. Please respecify.

TUNM001A

COL EXCLUDED FROM VIEW

Column &CDUCSFLD is excluded from view. It cannot be shifted to.

TUNM001B

COL UNKNOWN OR INVALID

Column &CDUCSFLD is not defined or is an invalid column name.

TUNM001E

UNSUPPORTED FUNCTION

Function requested is not supported for this screen. Request ignored.

TUNM001I

ROW &CDUDTCRP to &CDUDBCRP of &CDUROWS

Row &CDUTCRP through row &CDUBCRP (including excluded rows) of &CDUROWS rows.

TUNM001J

ROW &CDUDTCRP of &CDUROWS

Top row displayed is row &CDUTCRP of &CDUROWS rows. Rows are filtered out.

TUNM002E

INSUFFICIENT STORAGE

The Dynamic Area Manager cannot obtain enough storage to function.

TUNM002I

CUSTOMIZATION CANCELLED

All changes have been cancelled.

TUNM003E

INVALID SORT FIELD

The field name entered for sort is invalid. Please respecify.

TUNM004E

ASU INTERVAL INVALID

The ASU interval must be between 1 and 180. The default is 3 seconds.

TUNM005A

CUSTOMIZATION DELETED

Customization options for this panel have been deleted from your profile.

TUNM005B

CUSTOMIZATION SAVED

The current customization options have been saved to your profile.

TUNM005C

NO CUSTOMIZATION ALLOWED

Customization for this screen has not been defined.

TUNM005E

ISPF CALL ERROR

Error in ISPF call. R15=&CDUVR15 ISPF function name was &CDUVISFN.

TUNM005I

EXPORT CANCELLED

Export processing cancelled at user’s request.

TUNM006E

LOCATE COMMAND NOT DEFINED

No locate command is defined for this screen. Request is ignored.

TUNM006I

&CDUVEMEM SAVED

Member &CDUVEMEM saved in data set &CDUVEDSN.

TUNM006J

DATA SET SAVED

Data set &CDUVEDSN has been saved.

TUNM007E

INVALID LOCATE ARGUMENT

Argument entered for locate is missing or is invalid.

TUNM007W

LOCATE ARG NOT FOUND

Locate argument entered was not found for this screen.

TUNM008E

INVALID @DAM TOKEN

'Dynamic Area Manager received an invalid token. Request is terminated.

TUNM008W

INVALID MASK

Mask field entered at cursor location is invalid. Please respecify.

TUNM008Z

TOTALS NOT SUPPORTED

This screen does not support the TOTAL command.

TUNM009A

INVALID EXPORT RECLEN

Export data set length must be at least 80-bytes.

TUNM009B

SCREEN &CDXNAME CHANGED

The format of screen &CDXNAME has been changed.

TUNM009C

SCREEN &CDXNAME SAVED

The format of screen &CDXNAME has been saved in your ISPF profile.

TUNM009E

INVALID SORT COMMAND

Sort command or sort field is invalid. Please respecify.

TUNM009I

EXPORT DATA TRUNCATED

The export data set record length is not large enough to accommodate the width of the maximum length record. Record length required is &HLRECL.

TUNM009L

INVALID LINE COMMAND

Invalid line command entered. Please respecify.

TUNM009W

INVALID COMMAND

Command &ZCMD is invalid. Please respecify.

TUNM009Y

NO FIELDS TO THE RIGHT

No fields exist to the right. Scroll request ignored.

TUNM009X

OPERATOR NOT SUPPORTED

The only operators supported for non-numeric fields are "=" and "¬".

TUNM009Z

NO FIELDS TO THE LEFT

No fields exist to the left. Scroll request ignored.

TUNM010A

Not Usable

Not a usable view when analyzing with Normalized-Active; waits not analyzed.

TUNM010B

Invalid analysis option

Invalid analysis option for batch; enter NORMAL, ACTIVE, WAIT, or ALL.

TUNM010C

Tutorial Ended

The tutorial has been ended at the user's request.

TUNM010D

Duplicate Entry

Help entry not added. A duplicate entry already exists.

TUNM010E

Help entry added

Help entry added to content help table.

TUNM010F

Help entry updated

Help entry has been updated in table.

TUNM010G

Update not allowed

Distributed entries cannot be updated; use COPY to create a user entry that will supersede the distributed entry.

TUNM010H

Content missing

Content must be specified before continuing.

TUNM010I

Invalid or missing type

Content type must be specified and be one of the following types: CSECT, MAJDELY, MINDELAY, MODULE, DB2PLAN, DB2TYPE, CICSTRAN, IMSTRAN.

TUNM010J

Invalid help name

Help member name must be specified, must be a valid PDS or PDSE name, and must not begin with TUC.

TUNM010K

Invalid help topic name

Help topic name must be a valid PDS or PDSE name.

TUNM010L

Invalid level

Help level must be specified and must be 1, 2, or 3.

TUNM010M

Invalid or missing edit

The edit option must be specified and must be either YES or NO.

TUNM010N

Invalid content

Content for type &TYPE is invalid; it must be a valid &TYPE name before continuing.

TUNM010O

Invalid CICS transaction

Maximum length for a CICS transaction name is 4; correct before continuing.

TUNM010P

Invalid &TYPE

Maximum length for type &TYPE is 8 characters; correct before continuing.

TUNM010Q

Edit not allowed

Distributed help member cannot be updated; use COPY to create a user entry that will supersede the distributed entry and add the appropriate help text to the new user level entry.

TUNM010R

Delete not allowed

Distributed entries cannot be deleted.

TUNM010S

Help update is busy

Someone else is updating content-sensitive help; please try later.

TUNM010T

Help update unavailable

Content-sensitive help is currently unavailable.

TUNM010U

No ADDHELP for column

No content-sensitive help is defined for this column or content sensitive help is unavailable.

TUNM010V

Creating new help entry

New content sensitive help entry is going to be created for the item selected.

TUNM010W

Updating help entry

Content sensitive help currently exists for this entry.

TUNM010X

Copying help entry

A distributed content sensitive help entry is being used as a model for a new user level help entry.

TUNM010Y

Nothing selected

To invoke ADDHELP, enter ADDHELP on the command line and do NOT press enter. Move the cursor to the item you wish to add Content Sensitive help for and then press enter.

TUNM010Z

Cannot update help

Error occurred when opening help for update; return code = &RC; reason code = &RS; description (may be blank) = &desc.

TUNM011A

Member &member saved

Help member &MEMBER has been saved.

TUNM011B

Blank content selected

ADDHELP processing requires non-blank content; make sure the cursor position is on a non-blank field before pressing enter.

TUNM011C

STMT not available

STMT level histogram resolution is not available; the listing is either not registered for the CSECT or the registered listing is invalid; a grouping of 32 bytes has been substituted.

TUNM011D

Entry already exists

Entry already exists in the External Data Set List; entry was not added.

TUNM011E

Data set not allocated

Monitor data set &xdsn for user &userid cannot be allocated; note TSO message issued before this message for the allocation error and reason.

TUNM011F

Unsupported List Manager

DDIO is only supported for COBOL listings.

TUNM011G

Unable to allocate DDIO

DDIO file cannot be allocated; request is cancelled.

TUNM011H

Unable to alloc ABNLPARM

Temporary data set for ABNLPARM cannot be allocated; request is cancelled.

TUNM011I

Unable to alloc ABNLREPT

Temporary data set for ABNLREPT cannot be allocated; request is cancelled.

TUNM011J

invalid data set

&LISTMGR file selected is either invalid or missing; please respecify.

TUNM011K

CWDDSUTL error occurred

CWDDSUTL ended with an RC of &result.

TUNM011L

UIF has no profiles

There are no profiles to include from the User Information File: &xdsn

TUNM011M

Listing not found

CWDDSUTL ended with an RC of &result. Check to see that the member &ddiomem is in the DDIO file specified.

TUNM011N

Obtaining list from DDIO

CWDDSUTL is being called to obtain the listings; please be patient.

TUNM011O

Registering Listing

Listing is currently being registered; please be patient.

TUNM011P

Invalid DDIO Options

Program was not compiled with the proper DDIO options; contact your Systems Programmer for details.

TUNM011Q

Registration failed

Listing registration failed with an unrecognized error.

TUNM011R

Data set is not found

Data set &allocdsn could not be found.

TUNM011S

Data set is migrated

Data set &allocdsn is migrated and per user request has not been recalled.

TUNM011T

ERASE RC=&RC

Table ERASE return code is &RC for table &tabname.

TUNM011U

Allocation failed

CA Panvalet allocation failed for the PAN subsystem.

TUNM011V

Allocation failed

CA Librarian allocation failed for the LAM subsystem.

TUNM011W

TUNLAMDA failed

CA Librarian allocation utility TUNLAMDA failed with reason of &lamda.

TUNM011X

Profile has zero runs

Cannot include a Monitor definition profile without any monitor runs.

TUNM011Y

&CSECT is reregistered

&CSECT has been successfully re-registered.

&regmsg1

&regmsg2

&regmsg3

TUNM011Z

Help is unavailable

Help processing has not been initialized.

TUNM012A

Help member is not found

Help member &TOPIC is not found in the help library.

TUNM012B

Field contents invalid

This field can only contain YES, NO, or CONFIRM.

TUNM012C

Help text found

Copy requested, but help text already found in member.

TUNM012D

Not authorized

You are not authorized to use this server.

TUNM012E

Display Active failed

&TUNMSG1 &TUNMSGS &TUNMSG2

TUNM012F

Open/ CA MAT Abend

Abend occurred in Open/ CA MAT. Software record has been created, please contact Customer Support for assistance.

TUNM012G

Open/ CA MAT Error

Internal control block error. Please contact Customer Support for assistance. RC=&TUNRC RS=&TUNRS.

TUNM012H

Insufficient Storage

Request could not be processed because of a lack of storage either in the server or client.

TUNM012I

Open/ CA MAT Req Failed

Open/ CA MAT request failed.

TUNM012J

Server not found

CA MAT server &TUNSSID was not found.

TUNM012K

Server not active

CA MAT server &TUNSSID was not active.

TUNM012L

Unknown O-Tune Error

Unknown Open/ CA MAT failure. RC=&tunrc RS=&tunrs;
MSG1 = &TUNMSG1; MSG2 = &TUNMSG2.

TUNM012M

Release mismatch

CA MAT ISPF Client and server have incompatible releases.

TUNM012N

Open CA MAT Cmd Error

RC=&tunrc RS=&tunrs; &TUNMSG1; &TUNMSG2.

TUNM012O

System Defaults Missing

System Defaults could not be loaded from the Global Information File.

TUNM012P

User Defaults Missing

User Defaults could not be loaded from the Global Information File.

TUNM012Q

Invalid monitor request

&TUNMSG1

TUNM012R

Error reading listing

Error encountered reading the listing - &eiorc. Listing could not be registered.

TUNM012S

CWDDSUTL missing

CWDDSUTL utility for extracting listings from DDIO could not be found.

TUNM012T

Data Error

Unable to create Histogram for Module: &MODX Csect: &CSEX.

TUNM012U

Status failed

&TUNMSG1 &TUNMSGS &TUNMSG2

TUNM012V

Unsupported List Manager

IDEAL is only supported for IDEAL listings.

TUNM012W

Unsupported List Manager

IDEAL listings require the IDEAL list manager.

TUNM012X

No Listing to Browse

Permanent listings are not available with the IDEAL list manager.

TUNM012Y

No Listing to Export

Permanent listings are not available with the IDEAL list manager.

TUNM012Z

VLSUTIL not found

CA Ideal utility VLSUTIL was not found in any allocated load library. Unable to register CA Ideal programs.

TUNM013A

User exits cleared

User exits with names that begin with TNUDCM, TNUIDL, TNUADA, or TNUNAT have been cleared from your {local|global} monitor definitions.

TUNM013D

Prefix is not active

The &&prefix variable symbol is not part of the DSN cluster name specified for the User Information File (UIF). The USER_TABLES_CLUSTER_DSN is specified in member TUNSDEFS of the PARM library.

TUNM013E

Invalid command

An invalid command was passed to this procedure; ADDHELP is the only supported command.

TUNM013F

Cannot update help

&OWNER on &SYSTEM is currently accessing help in &GDSN.; all update functions are disabled.

TUNM013G

Help update not allowed

The security system has indicated that you are not allowed to update Content-sensitive help; all update functions are disabled.

TUNM013H

&TUNSMSG

&TUNLMSG

TUNM013I

Cannot update help

Permission to update Content-sensitive help has not been granted. Reason: &TUNSAF.

TUNM013J

Invalid command

An invalid primary command was entered. Please press HELP for a list of supported commands.

TUNM013K

Display Error

An internal display error was detected. RC=&rc RS=&rs.

TUNM013L

Invalid line command

An invalid line command was entered. Please press HELP for a list of supported commands.

TUNM013M

Not a local system

You may use the Display Active command for ASIDs running on the local system only.

TUNM013N

Not in Alternate Access

This facility is not available using MainView Alternate Access terminal session support.

TUNM013O

SQL not from Catalog

This SQL is not from the DB2 catalog. It is possible that it is not accurate - please exercise the proper caution.

TUNM013P

Continuing from bookmark

CA MAT tutorial continuing at the location bookmarked on the last exit.

TUNM013Q

Dates do not match

The date the monitored program was compiled, &csdate, and the date of compilation of the registered listing, &ldate, do not match. This may cause misleading or inaccurate information to be displayed.

TUNM013R

Compilers do not match

The compiler id from the monitored program, &progfmid, and the listing, &compiler, do not match. This may cause misleading or inaccurate information to be displayed.

TUNM013S

Sizes do not match

The program size, &psize, and the listing size, &lsize, do not match. This may cause misleading or inaccurate information to be displayed.

TUNM013T

Not authorized

Permission to update System Administration functions has not been granted. Reason: &TUNSAF.

TUNM013U

Listing from Global File

Registered program listing for &CSECT was not found in your User Information File (UIF). Listing was found in the Global Information File (GIF) - this listing is being used. Use the REGister command to register the listings locally.

TUNM013V

SERCOPY error occurred

The Changeman program SERCOPY ended with rc = &RESULT. Verify that the SERCOPY program exists in &CHMLINK.

TUNM013W

Profile has zero runs

No monitor data available to analyze.

TUNM013X

Registering &lmember

&allocdsn is currently being registered.

TUNM013Y

Need to register module

The Csect you are attempting to register requires that the module be registered. You will need the output from the final LINK-EDIT step (with option MAP=YES specified). Issue the MODule command on the Registered Listings panel.

TUNM013Z

Sizes do not match

The program size, &psize, and the listing size, &xsize, do not match. This may cause misleading or inaccurate information to be displayed. If this is a PL/I program, you may need to reregister the listing with the LIST option specified.

TUNM014A

Allocation failed

CA Endevor allocation failed.

TUNM014B

Invalid Endevor Options

Program was not compiled with the proper Endevor options; contact your Systems Programmer for details.

TUNM014C

Unable to allocate file

Endevor file cannot be allocated; request is cancelled.

TUNM014D

Unable to alloc BSTIPT01

Temporary data set for BSTIPT01 cannot be allocated; request is cancelled.

TUNM014E

Unable to alloc C1PRINT1

Temporary data set for C1PRINT1 cannot be allocated; request is cancelled.

TUNM014F

ENDEVOR error occurred

The Endevor program NDVRC1 ended with rc = &RESULT. Data set &c1msg may contain error information.

TUNM014G

SERCOPY not found

The Changeman program SERCOPY was not found in LINKLIST. Specify the load library where the SERCOPY program resides.

TUNM014H

Transaction only mode

The WebSphere monitor definition was specified without Application URL filters. Application/Via/Current class data is not available. You can use the transactions displayed to define URL filters for subsequent monitors.

TUNM014I

Unable to allocate file

The work file for the batch report job cannot be allocated; the EDIT request is cancelled. You can still use the Batch Report panel to change and submit the job. Any changes made on the Batch Report panel will be saved.

TUNM014J

Batch Report Job saved

Any changes you made to the batch report job were saved in data set &tunjcl. The profile was not updated. However, any changes made on the Batch Report panel will be saved.

TUNM014K

Batch Report Job not saved

Any changes you made to the batch report job were not saved because the work file was allocated to a temporary data set. The profile was not updated. However, any changes made on the Batch Report panel will be saved.

TUNM014L

Invalid ProtSym options

Program was not compiled with the proper PROTSYM options; contact your Systems Programmer for details.

TUNM014M

Unable to allocate File

PROTSYM file cannot be allocated; request is cancelled.

TUNM014N

Unable to alloc CARDS

Temporary data set for CARDS cannot be allocated; request is cancelled.

TUNM014O

Unable to alloc OUTPUT

Temporary data set for OUTPUT cannot be allocated; request is cancelled.

TUNM014P

ProtSym error occurred

The PROTSYM program IN25UTIL ended with rc = &RESULT. Data set &protmsg may contain error information.

TUNM020A

Jobname is invalid

Jobname &jobid was not found in the system.

TUNM020B

Job &jobid not found

&jobid was not found in the system.

TUNM020C

Job &jobid ended

&jobid has ended.

TUNM020D

&TUNMSMSG

&TUNMLMSG

TUNM020E

Switched to &jobid

PEEK is now looking at the address space of &jobid.

TUNM020F

Invalid number

Number entered was not a valid numeric.

TUNM020G

Server not active'

The Server &TUNSSID is not active or is not found.

TUNM020H

XM Call failed.

Cross Memory Peek call failed with an RC of &RC.

TUNM020I

ASID is inactive

The specified address space in not active.

TUNM020J

Peek access denied

The security system has denied your access to the PEEK processor.

TUNM030

GIF mismatch detected

The Global Information File (GIF) use by the CA Mainframe Application Tuner Server &TUNSSID does not match the GIF for this client. You can use Interactive Analysis for existing Monitor Data Sets, but should not invoke any new monitors.

TUNM031

&SMSG

&LMSG

TUNM032

&SMSG

&LMSG

TUNM033

Invalid file attributes

CA MAT only supports listing data sets with a data set organization of physical sequential (PS) or partitioned (PO) with fixed or variable length records. PDSe (partitioned extended) files are also supported.

TUNM034

Registration Severe Error

Severe error occurred during Listing Registration. RC=&result.

TUNM035

Allocation Failed

Allocation failed for listing data set. Listing registration is cancelled.

TUNM036

Listing not readable

EXECIO failed with a return code of &eiorc and failed to read the listing. Listing registration is cancelled.

TUNM037

CSECT name missing

No CSECT name is associated with the load module. The started task was not able to resolve a CSECT name within the load module. Make sure the started task has READ access defined to the security system for the load libraries for the application.

TUNM038

Invalid listing target

Listings are not available for pseudo entities.

TUNM039

&ZERRSM

&ZERRLM

TUNM040A

Invalid schedule date

The date specified is invalid. It must either be in the format of YYYY/MM/DD or one of the following symbolics: TODAY, TOMORROW, MONDAY TUESDAY, WEDNESDAY, THURSDAY, FRIDAY, SATURDAY, SUNDAY, &&TODAY, &&TOMORROW, &&MONDAY, &&TUESDAY, &&WEDNESDAY, &&THURSDAY, &&FRIDAY, &&SATURDAY, or &&SUNDAY.

TUNM040B

Invalid selection char

If you wish to select an item, you must use a forward slash (/).

TUNM040C

Invalid time

Time must be specified as a 24-hour clock in the format of HHMM.

TUNM040D

INVALID GROUPED DAYS

Either select Weekdays and/or Weekends, or specific days.

TUNM040E

SELECT A DAY

At least one day must be specified.

TUNM040F

Invalid times

Please leave no imbedded blank time ranges in the panel.

TUNM040G

Invalid days

Number of schedule days is not numeric.

TUNM040H

Mutually exclusive

You cannot specify an ending date and a day range. Please select one or the other.

TUNM040I

Invalid date variable

If date variables are used, they must be used in both starting and ending date ranges.

TUNM040J

Ending date missing

Either an ending date or number of days is required

TUNM040K

Duplicate entry

Duplicate monitor data set entry. Please respecify.

TUNM040L

Invalid date combination

If the starting date is a variable, then the ending date must also be a variable, if specified. You can use number of days the monitor is valid for, instead of an ending date variable.

TUNM040M

Invalid date range

Date range specified is invalid. Most likely, the starting date is later than the ending date.

TUNM040N

Duplicate schedule name

A schedule with the name specified already exists. Please change the name before continuing. If the name is not listed on the panel, then the schedule belongs to a global monitor profile of the same name.

TUNM040O

Invalid schedule name

The first character of the schedule name must be alphabetic or a National Character. There are also no imbedded spaces permitted.

TUNM040P

Schedule name missing

Please specify a schedule name.

TUNM040Q

TUNSDEF table missing

The System Defaults Table (TUNSDEF) is missing from the Global information file (GIF). Using defaults. Review the Installation Guide for information pertaining to the TUNSDEF table.

TUNM040R

Internal CA MAT error

An internal error occurred inside of CA MAT. Contact Customer support with the following information: RC=&TUNRS RS=&TUNRS MSG1=&TUNMSG1 MSG2=&TUNMSG1

TUNM040S

Request timed-out

The request made to the server has timed out.

TUNM040T

UIF allocate failed

Request could not be completed. The server could not allocate your UIF to process the request.

TUNM040U

No matching systems

No matching systems found. Please respecify.

TUNM040V

Group has been copied

Group &xgroup has been copied to &group. Please edit &group now or press END to return.

TUNM040W

Duplicate entry

Duplicate profile name. Please respecify.

TUNM040X

Import failed

The specified data set could not be restored.

TUNM040Y

Data set exists

&msgdsn already exists. Please specify a different name.

TUNM050A

&MSGENV error

for &MSGCMD in program &MSGPROG, rc=&MSGRC, loc=&MSGLOC

TUNM050B

&TRACPRG &TRACLOC

&TRACMSG