Previous Topic: TN31 Messages

Next Topic: TN33 Messages

TN32 Messages

TN3200W Control card error in SYS1.PARMLIB(BBSEC)

Reason:

An invalid control statement was encountered in the member 'SYS1.PARMLIB(BBSEC). This message is always followed by the message TN3024W.

Action:

The control statement is ignored.

Refer to the definition of BBSEC control statements in the Installation Guide. Correct the error and restart the server address space.

Origin: TNSSEC

TN3204W 'control card in error'

Reason:

This message is always preceded by the message TN3200W. This line is the control card that was determined to be in error while processing security definitions in SYS1.PARMLIB(BBSEC).

Action:

The control card is ignored.

Refer to the definition of BBSEC control cards in the Installation Guide. Correct the error and restart the server address space.

Origin: TNSSEC

TN3205W Cannot allocate SYS1.PARMLIB

Reason:

During server space initialization for CA Mainframe Application Tuner, the SAF interface initialization routine could not allocate SYS1.PARMLIB and therefore could not open the BBSEC member containing the security definitions for CA Mainframe Application Tuner.

Action:

Processing continues without creating the security tables.

Determine if the SYS1.PARMLIB data set is catalogued on the system that CA Mainframe Application Tuner is starting on. Restart the server address space.

Origin: TNSSEC

TN3208W BBSEC ended prior to completion of a continuation

Reason:

While processing a continuation of a BBSEC control statement, no more keywords were found.

Action:

The control card is ignored.

Refer to the definition of BBSEC control cards in the Installation Guide. Correct the error and restart the server address space.

Origin: TNSSEC

TN3209I Security definitions retrieved from SYS1.PARMLIB

Reason:

BBSEC successfully retrieved all security definitions from SYS1.PARMLIB(BBSEC) that pertained to CA Mainframe Application Tuner.

Action:

The server space initialization continues.

Origin: TNSSEC

TN3230E SSCT not valid -- U3305 follows

Reason:

During server space initialization, the SSCT was found not to contain a valid extension.

Action:

CA Mainframe Application Tuner terminates with a U3305 abend. Contact Customer Support.

Origin: TNSDPSD

TN3240W RACROUTE ATTR=READ test failed -- data set will not be allocated

Reason:

During allocation of a user or system data set the RACROUTE test, designed to determine if a data set is available to read, received a return code other than 0.

The name of the data set is in the TN3241W message that follows.

Action:

CA Mainframe Application Tuner continues to initialize the server space or monitor request (depending on where the RACROUTE failure is detected). CA Mainframe Application Tuner will not attempt to allocate or open this data set.

Origin: TNCVERR

TN3241W Data set: data set name

Reason:

Refer to message TN3240W for a description of this message.

Action:

Same as TN3240W.

Origin: TNCVERR