Previous Topic: Column Descriptions

Next Topic: TOP Scope Facility

Alert Management

Alert processing automatically identifies critical situations within a job step that require measurement by CA Mainframe Application Tuner. The alert is issued automatically by Performance Management Assistant when it recognizes these situations:

Additionally, the user can manually issue alerts explicitly for job steps by using the online Alert Management option.

The Alert Management option provides all the necessary information for the APM Team to handle the alert. Information is provided in the form of state and reason codes that identify the situation. The following table provides a description of these codes:

State Code

Reason Code

Long Description

PEND

 

Performance Management Assistant provides a CA MAT measurement. A measurement is available if the alert state is changed to OPEN.

ELPS

SRVU

SUIO

ELIO

CPIO

The state was created by job APCXJSMF as a result of statistical calculations based on absolute values.

The state was created by job APCXJSMF as a result of statistical calculations based on performance indexes.

ALTH

The state was created by job APCXJSMF by comparing SMF consumption values of a job to the defined alert thresholds.

MODC

The state was created by job APCXJLIB as a result of a changed module.

SRVR

The state was created by the server.

USER

The state was created by an online user.

OPEN

 

Performance Management Assistant has information about an alert, either a CA MAT measurement or the user text.

ELPS

SRVU

MODC

USER

The state was changed from PEND to OPEN by job APCYJLNA for one of the following reasons:

A CA MAT measurement existed for a job step that was in the TOP Scope and had exceeded its statistical limits.

A measurement was stored in any case by user definition.

No further alerts are created except those of changed modules.

TEXT

The state was created by an online user to indicate that no measurement was requested; however, user text information was provided.

CHCK

A user has initiated an alert for checkpoint writing.

REV

 

An online user selected an alert for review/inspection.

all

The state was changed by an online user by using command R(eview) in the Alert List Panel. No further alerts are provided by Performance Management Assistant.

CUSE

 

An online user closed the alert.

all

The state was changed by an online user by using command C(lose) in the Alert List Panel.

CTHR

 

PMA closed the alert automatically. No measurement is provided.

ELPS

SRVU

MODC

USER

The state was changed by job APCYJLNA because the measured job step abended or a CA MAT Scope change has affected a PEND alert.

CIMP

 

PMA closed the alert automatically. No measurement is provided.

ELPS

SRVU

MODC

The state was changed by job APCYJLNA because the consumption values of the measurement did not exceed the statistical-based alert values or a TOP Scope change affected a PEND alert.

CMUL

 

PMA closed the alert and temporarily stopped further alerts automatically.

ELPS

SRVU

MODC

The state was changed by job APCYJLNA because more than three contiguous alerts with CTHR or CIMP were detected. No further CA MAT measurements are provided until a module change is detected or an online user uses the D(elete) command in the Alert List Panel.

COVT

 

An online user closed the alert and took over the statistical data.

ELPS

SRVU

The state was changed by an online user by using the overtake command O in the Alert List panel. In this case, the runaway values are the new statistical base for future tests.