Previous Topic: Set Sample Recording Frequency

Next Topic: Sample Command Audit Report (CN) Report

Sample Command for Record Collection

The following example shows how to begin the record collection process for the CA MIC Command Audit report. This example indicates data sampling every 30 seconds, and a statistical record recording interval of every hour:

SETOPTION GCMF STATCOLLECT(SUBTYPE=CN) STATCYCLE=30, STATINTERVAL=60

Note: The STATCYCLE and STATINTERVAL values apply to all record collection subtypes for a given CA MIM facility (GCMF, and so on).

Once the statistical record collection process has begun, records are collected and written to the SMF data sets. You need to use your site‑specific procedures for dumping the records to physical sequential data sets that can be used by CA MIM to produce reports.

Notes: