The COMPRESS parameter member update report shows you how to revise the FILE statements in prefix.MICS.PARMS(COMPRESS) to achieve the compression benefits shown on the other Compression Recommendation Reports. The report shows all of the FILE statements, highlighting those that need to be changed by showing the changed timespan indicator in lowercase text and placing a changed flag to the right of the statement. (Changing the parameter does not implement compression, though. CYCLEGEN, BACKUP, and RESTORE must be successfully completed to make the change, as outlined in Section 6.2.2.4 of the CA MICS System Modification Guide.) A sample report is shown below:
COMPRESS Parameter Member Update Report --------------------------------------- CA MICS Complex Name: MDI.DIA6100-COMPRESSION COMPLEX Unit Id: P Unit Type: PRIMARY Date: 28APR00 Page 1 Percent savings limit specified: 0.10 % (Use this report to update the FILE statements in the MDI.DIA6100P.PARMS(COMPRESS) member. All changes are shown in lower case.) ------------------------------------------------------------ FILE SMF BAT_JS n Y Y Y Y (Changed) FILE SMF BAT_ST Y Y Y Y Y FILE SMF BAT_TP Y Y Y Y Y FILE SMF BAT_TS n Y Y Y Y (Changed) FILE SMF BATATP Y Y Y Y Y FILE SMF BATJOB n Y Y Y Y (Changed) FILE SMF BATPGM y Y Y Y Y (Changed) FILE SMF BATSFH N N N N N FILE SMF BATSPL n Y Y Y Y (Changed) FILE SMF BATWDA Y Y Y Y Y FILE SMF OPSAVL Y Y Y Y Y FILE SMF OPSCON Y Y Y Y Y FILE SMF OPSCTF Y Y Y Y Y FILE SMF OPSOPI Y Y Y Y Y
| Copyright © 2012 CA. All rights reserved. | Tell Technical Publications how we can improve this information |