Previous Topic: 3.8.3 Adding a New Product to a New Database Unit

Next Topic: 3.8.3.2 Generate the New Database Unit(s)

3.8.3.1 Define and Generate New Product(s)


__  1. Define Products to be Generated

       Check off the products that require generation:

       Note: CAP, PER, STG, LDE, VCC, and VMT do not require 
       generation.

       Standard Products

       ___ BAS - CA MICS base platform
       ___ ACT - Accounting and Chargeback Option
       ___ AST - CA ASTEX Option
       ___ AUM - Analyzer Option for MeasureWare
       ___ CIC - Analyzer Option for CICS
       ___ DB2 - Analyzer Option for DB2
       ___ DEX - Analyzer Option for VAX/VMS
       ___ HSM - VCA support for DFHSM
       ___ IDM - Analyzer Option for CA IDMS
       ___ IMS - Analyzer Option for IMS
       ___ MQS - Analyzer Option for MQSeries
       ___ PWR - Analyzer Option for VSE/Power
       ___ RMF - Hardware and SCP Analyzer
       ___ SMF - Batch and Operations Analyzer
       ___ SNT - Network Analyzer Option
       ___ SRL - System Reliability Analyzer Option
       ___ TDM - Tandem Option
       ___ TLM - Tape Analyzer Option, TLM Component
       ___ TSO - Analyzer for TSO
       ___ VCA - Space Analyzer Option
       ___ VMC - Analyzer Option for VM/CMS
       ___ VTS - Tape Analyzer Option, VTS Component
       ___ WEB - Web Analyzer Option

       Field Developed Applications (Including MSI and MTI)

       ___ (___) - ____________________________
       ___ (___) - ____________________________
       ___ (___) - ____________________________

       +---------------------------------------------------+
       | Reference(s):  Section 3.4.1                      |
       +---------------------------------------------------+


 ************************************************************
 *  Repeat Steps 2 through 6 in this section for all        *
 *  products that have been checked off for generation.     *
 ************************************************************

__  2. Review Component Generation Options

       Review component generation options in Chapter 7 of
       the product guides for the data integration
       applications (DIAs) you are installing.  Some products
       provide global element tailoring options that you may
       wish to review.  Products that process user SMF data
       sources also provide an option for record selection.

       +---------------------------------------------------+
       |Reference(s):Section 3.4.2                         |
       |             Section 4.4                           |
       |             Section 4.2, System Modification Guide|
       |             Chapter 7, ccc Analyzer Guide(s)      |
       +---------------------------------------------------+


__  3. (CONDITIONAL) Copy Load Module for the CICS Analyzer


       Copy the appropriate load modules for the CICS
       Analyzer to the sharedprefix.MICS.LOAD library based
       on your installation's needs.

       INPUT SOURCE                      Load Module
       ------------                      -----------
       The Monitor
           Versions 8.0/8.1, 2.0/2.1       $CRCPRS
           Versions 7.0/7.1                TMV611

       EPILOG 1000                         BGUDCMP

       +---------------------------------------------------+
       | Reference(s):  Section 6.1, CICS Analyzer Guide   |
       +---------------------------------------------------+


__  4. (CONDITIONAL) Define Appropriate PARMS Members


       Customize the PARMS members that define account
       codes, cost center codes, and the exit routines with
       which they are associated.

       For the ccc Analyzer and Other Standard Products
       (Including FDAs, MSI and MTI):

           cccACCT  - Account Code Specification
           cccACRT  - Account Code Exit Routine

       For Batch and Operations Analyzer (SMF):

           ACCOUNT  - Batch Accounting Structure
           ACCTRTE  - Batch Accounting Exit Routine
       For Accounting and Chargeback (ACT):

           COSTCTR  - Accounting Cost Center Structure
           COSTRTE  - Accounting Cost Center Exit Routine

       For VAX/VMS Analyzer (DEX):

           DEXACRTD - DEX Disk Usage Accounting Exit Routine
       +---------------------------------------------------+
       | Reference(s):  Section 2.3.1.7, all subsections   |
       |                Section 4.1, Accounting and        |
       |                             Chargeback User Guide |
       |                Chapter 7, ccc Analyzer Guide(s)   |
       +---------------------------------------------------+


       For MTI Components supporting account codes:

           cccACCT  - Account Code Specification
           cccACRT  - Account Code Exit Routine

__  5. (CONDITIONAL) Execute JCLGENUC for MTI Components


       During the creation of an MTI component,
       sharedprefix.MICS.PARMS(cccINPUT) is generated.  This
       member contains the data sets that will be used during
       component creation to determine which CA NSM
       performance management resources and resource-subtypes
       will be included in the component.

       Ensure that this member contains the input data sets
       for this component.
       If changes were made to cccINPUT, then

       __ Edit sharedprefix.MICS.PARMS(JCLGENUC) and copy the
          contents of sharedprefix.MICS.PARMS(JCL$0ccc) into
          this member (JCLGENUC).

       __ Submit the following job:

            'sharedprefix.MICS.CNTL(JCLGENUC)'
       Ensure that there are no error messages in MICSLOG or
       SYSTSPRT, that the MICSLOG contains the normal
       termination message BAS10999I, and that the job
       completes with a condition code of zero.

       +---------------------------------------------------+
       |Reference(s):Section 8.5, System Modification Guide|
       +---------------------------------------------------+


__  6. Execute cccCGEN for Each Product

       Generate the product.

       Run the component generation process for each product,
       where ccc is the component identifier.

       Submit the following job:

'        sharedprefix.MICS.CNTL(cccCGEN)' 

       Ensure that there are no error messages in ISPLOG 
       and MICSLOG; that MICSLOG contains the normal termination 
       message, BAS60199I; and that the job completes with a 
       condition code of zero. 

       Check off each component generation as it is done,
       running the BASCGEN first:

          __ BASCGEN

          __ ACTCGEN __ ASTCGEN __ AUMCGEN __ CICCGEN
          __ DB2CGEN __ DEXCGEN __ HSMCGEN __ IDMCGEN
          __ IMSCGEN __ MQSCGEN __ PWRCGEN __ RMFCGEN
          __ SMFCGEN __ SNTCGEN __ SRLCGEN __ TLMCGEN
          __ TDMCGEN __ TSOCGEN __ VCACGEN __ VMCCGEN
          __ VTSCGEN __ WEBCGEN

          __ cccCGEN for FDA, MSI, and MTI (if applicable)


       +---------------------------------------------------+
       | Reference(s):  Section 3.4.3                      |
       +---------------------------------------------------+

          MTI Components

          ___ (___) - ____________________________
          ___ (___) - ____________________________

 ************************************************************
 *  Repeat Steps 2 through 6 in this section for all        *