1. OVERVIEW › 1.4 Online Facility Tutorial › 1.4.3 Performance Manager Analysis Inquiries › 1.4.3.5 Executing an Analysis Inquiry
1.4.3.5 Executing an Analysis Inquiry
To select an analysis inquiry for execution, type S (select)
in the Cmd column of the inquiry on the main Performance
Manager Catalog panel shown in Figure 1-24.
/------------------------ Performance Manager Catalog -----------------------\
|Command ==> Scroll ===> PAGE |
| |
|Catalog ===> PRIVATE (PRIVATE/SHARED) Catalog Group ===> PERFORM |
|Select Mode ===> EXECUTE (EXECUTE/MODIFY) Name (subset display) ===>________|
| |
|Line Cmds: S Select I Insert R Repeat C Copy D Delete |
| |
|Cmd Name Title Date Time Type |
| - -------- ---------------------------------------- -------- ----- ------|
| S WKLD1 Data Clustering yy/mm/dd 13:24 PERCLU|
|******************************************************************************|
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
\----------------------------------------------------------------------------/
Figure 1-24. Selecting an Inquiry for Execution
The MICF Execution panel is shown in Figure 1-25.
/-------------------------- MICF Execution ------------------------------------\
|Command ===> |
| |
|Executing CA MICS Inquiry: WKLD1 -Testing fix for PE177130 - Invalid IF |
| |
|Inquiry Execution Mode ===> BATCH (BATCH/FOREGROUND/DMS) |
|Override Execution Options ===> N (Y/N) |
|SAS/DMS Options: Resume ===> N (Y/N) Output Replay ===> Y (Y/N) |
| |
|Press ENTER to execute the inquiry, or press END to cancel execution. |
| |
|---------------------- Batch Job Submission Parameters ---------------------|
|Edit Generated Jobstream ===> Y (Y/N) Hold Inq. Output for Replay ===> N (Y/N|
| |
|Sysout Class ===> * Sysout Form ===> ____ |
|Destination ===> _________________ Sysout Writer ===> ________|
|Sysout Parms. ===> ___________________________________________________________|
| |
|Job Card Information: |
| ===> //jobname JOB (accounting information), |
| ===> //MSGLEVEL=(1,1),MSGCLASS=A,PRTY=5 |
| ===> //* |
| ===> //* |
\----------------------------------------------------------------------------/
Figure 1-25. CA MICS Data Base Inquiry Execution Panel
The MICF Execution screen offers you the following execution
options:
o Selecting the Execution Mode
o Overriding the Default Execution Options
o Overriding the Default Job Submission Parameters
After you specify the options you desire and press ENTER, you
are provided with a fifth option:
o Selecting Execution-Time Data
Each of these options is discussed next.
1 - Selecting the Execution Mode
2 - Overriding the Default Execution Options
3 - Overriding the Default Job Submission Parameters
4 - Selecting Execution-Time Data