Previous Topic: E.6.4.1 Browse UNITGEN Lock Data Set

Next Topic: Appendix F.  LIBRARIES USED BY THE PSP

E.6.4.2 Forced UNITGEN Lock Reset

______________________________________________________________________________
--------------------------  Forced UNITGEN Lock Reset -------------------------
Command ===>
Enter END command to continue or CANCEL command to exit

Please confirm forced reset of the composite UNITGEN checklist lock:
  Enter YES or NO    => NO

Unlock job:
  Edit JCL           => YES        (YES/NO)
  SYSOUT class       => A  Form    => ________  Code => ________
                           Program => ________
  Job statement:
      //jobname  JOB  (ACCTCODE),'MICS JOB',
      //       NOTIFY=&sysuid
      //*
      //*
_______________________________________________________________________________

Forced UNITGEN Lock Reset panel (PSPUURES)


A job is submitted to force a reset of the UNITGEN checklist
lock.  This function should only be used when you really
don't want to finish a composite UNITGEN checklist and are
prepared to start over with a new one.

****  Data Entry Instructions  ****

Please confirm forced reset, Enter YES or NO - Required.
Defaults to NO. You have to confirm the reset with YES;
otherwise no action is taken.

Edit JCL - Required.  Defaults to the last value specified
for this parameter.  Specify YES to display the job stream
using the PDF EDIT service prior to executing this job
stream.  Specify NO to bypass the job stream display.

SYSOUT class - Required.  Defaults to the last value
specified for this parameter, A-Z, 0-9, or *.  This is the
SYSOUT class for printing the messages. Normal SYSOUT options
can be specified to handle special forms.

Job statement - Required.  Data entry fields are provided for
four lines of job statement information.  This job statement
will be followed by the generated JCL statements to reset the
UNITGEN lock.