5. FILES › 5.3 Operations Information Area Files › 5.3.1 Operations Incident File (OPSOPI) › 5.3.1.3 OPSOPI Usage Considerations
5.3.1.3 OPSOPI Usage Considerations
Special considerations or techniques related to using the
OPSOPI file are provided below.
1. The data elements in this file are set relative to
specific events. The contents of the data elements for
specific events are listed below:
The data for the 'IPL' event is obtained from the SMF
type 0 (IPL) record.
EVENT='IPL'
ENDTS - IPL Time Stamp
OPIBFSZ - Buffer Size (SMF)
OPIJWTM - Maximum Job Wait Time (JWT)
OPIRSSZ - Real Memory Size
OPISOPNS - Bit Pattern of SMF Options
OPITREC - Temporary DS Recording (Y/N)
OPIVSSZ - Virtual Memory Size
The data for the 'DATA LOST' event is obtained from the
SMF type 7 (Data Lost) record.
EVENT='DATA LOST'
ENDTS - End Of Data Lost Condition
OPIRLOST - SMF Records Lost
STARTTS - Start Of Data Lost Condition
The data for the 'SMF STATUS' or 'LOG STRM n' event is
obtained from the SMF type 23 (SMF Status) record.
(LOG STRM n is the log stream number)
EVENT='SMF STATUS' OR EVENT='LOG STRM n'.
ENDTS - Time Status Record Was Written
OPIBFNM - SMF Buffers Written
OPIBFSUS - SMF Buffer Suspensions
OPIINTTM - SMF Recording Interval
OPIMXUBF - Maximum SMF Buffers In Use At One Time
OPIRECNM - SMF Records Written
OPIFRREQ - Number Fixed Frames Requested
OPIFXREQ - Number Fix Requests Issued
OPIGMREQ - Number of Getmain Requests
OPIIO - Total Number I/O's
OPINFFLT - Number Non-first Reference Faults Taken
OPIPGBKD - Pages Backed During Getmain Requests
OPIRFFLT - Number First Reference Faults Taken
OPISRBDS - Number SRB Dispatches
OPITCBDS - Number Unlocked TCB Dispatches
OPILSBFT - Logstream Total Buffer Storage Used
OPILSWLE - Buffer Warning Level In Effect
OPILSDSP - DSPSIZMAX In Effect
OPILSBFA - Logstream Buffer Allocation Amount
OPILSHWM - Logstream High Water Mark Buffer Alloc
OPILSBSM - Logstream Buffer Storage Maximum
OPILSBWL - Logstream Buffer Warning Level
STARTTS - Start of Interval
The data for the 'TIOC INIT' event is obtained from the
SMF type 31 (TIOC Initialization) record.
EVENT='TIOC INIT'
ENDTS - Time Of TIOC Initialization
OPIBFSZ - Buffer Size (TIOC)
OPIFQBF - Free Queue Buffers
OPIMXLBF - Max Buffers Before LWAIT
OPIMXOBF - Max Buffers Before OWAIT
OPIOTHR - OWAIT Threshold Buffers
OPIRTHR - Restart Threshold Buffers
OPITBFNO - Number Of TSO Buffers
OPITSBSZ - Terminal Status Block Size
The data for the 'JES START' event is obtained from the
SMF type 43 (JES Start) record.
EVENT='JES2'
ENDTS - Time Of JES Start
OPIAINIT - JES2 Auto Initiator Req (Y/N)
OPICMD - Operator Command
= 'S JES2'
= '$E SYS'
OPILREPL - JES2 List Repl Card (Y/N)
OPISTYP - Type Of Start (C/W)
OPISYST - JES2 Syst For Job Proc Reclaim
EVENT='JES3'
ENDTS - Time Of JES Start
OPIOLOC - JES3 Init Deck Origin (N/M/U)
OPIONM - JES3 Init Origin Name
OPIPNM - JES3 Procedure Name
OPIPROC - JES3 Processor Started (G/L/I)
OPISTYP - Type Of Start (C/W/H/Q)
The data for the 'JES STOP' event is obtained from the
SMF type 45 (JES Stop) record.
EVENT='JES2 STOP'
ENDTS - Time Of JES Stop
TERMCODE - Completion Code
OPICMD - Operator Command
= 'ABEND'
= '$P JES2'
EVENT='JES3 STOP'
ENDTS - Time Of JES Stop
TERMCODE - Completion Code
OPICMD - Operator Command
= 'ABEND'
= 'P JES3'
= 'SYS INT'
The data for the 'SET TIME' event is obtained from the
SMF type 90 subtype 1 (System Status) record.
EVENT='SET TIME'
ENDTS - Time Of SET Command
OPINDTS - Time After SET Command
OPIODTS - Time Before SET Command
The data for the 'SET DATE' event is obtained from the
SMF type 90 subtype 2 (System Status) record.
EVENT='SET DATE'
ENDTS - Time Of SET Command
OPINDTS - Time After SET Command
OPIODTS - Time Before SET Command
The data for the 'SETDMN' event is obtained from the SMF
type 90 subtype 3 (System Status) record.
EVENT='SETDMN'
DOMAIN - Domain Number
ENDTS - Time Of SET Command
OPIDMNCG - Min MPL Changed (Y/N)
OPIDMXCG - Max MPL Changed (Y/N)
OPIDMOCG - Chg (WT/AOBJ/DOBJ/FWKL)
OPIEDGTS - Incident Time (GMT)
OPIMNMPL - New Minimum MPL
OPIMXMPL - New Maximum MPL
OPIOFCTL - New (WT/AOBJ/DOBJ/FWKL) Value
The data for the 'SET IPS' event is obtained from the SMF
type 90 subtype 4 (System Status) record.
EVENT='SET IPS'
ENDTS - Time Of SET Command
OPIEDGTS - Incident Time (GMT)
OPINM1 - Old Parmlib Member Name
OPINM2 - New Parmlib Member Name
The data for the 'SET SMF' event is obtained from the SMF
type 90 subtype 5 (System Status) record.
The data for the 'IPL SMF' event is obtained from the SMF
type 90 subtype 9 (System Status) record.
The data for the 'SETSMF' event is obtained from the SMF
type 90 subtype 13 (System Status) record.
The data for the 'SET SMF (Restart)' event is obtained
from the SMF type 90 subtype 15 (System Status) record.
EVENT='SET SMF'/'IPL SMF'/'SETSMF'/'SET SMF (RESTART)'
ENDTS - Time Of EVENT
OPIDETR - SMF Detail Recording (Y/N)
OPIEXT1-15 - SMF Active Exits
OPIINTTM - SMF Recording Interval
OPIIPLTS - IPL Time
OPIJWTM - Maximum Job Wait Time (JWT)
OPILDSN - LISTDSN Option (Y/N)
OPILSTDS - LASTDS Opt (HALT/MSG)
OPIMNBF - Minimum SMF Buffers
OPIMRTM - Maximum SMF Dormant Time (MAXDORM)
OPIMXBF - Maximum SMF Buffers
OPINM1-5 - SYS1.MANx Dataset Names
OPINOBUF - NOBUFFS Opt (HALT/MSG)
OPIPROPT - PROMPT Opt (LIST/ALL/IPLR/NONE)
OPIRECDS - Bit Pattern of SMF Recs
OPISTTM - STATUS Interval
OPISUBSY - SMF Subsystem Name
OPITREC - Temporary DS Recording (Y/N)
The data for the 'SWITCH SMF' event is obtained from the
SMF type 90 subtype 6 (System Status) record.
EVENT='SWITCH SMF'
ENDTS - Time Of SWITCH Command
OPIIPLTS - IPL Time
OPINM1 - Old Recording Data Set Name
OPINM2 - New Recording Data Set Name
The data for the 'HALT EOD' event is obtained from the
SMF type 90 subtype 7 (System Status) record.
EVENT='HALT EOD'
ENDTS - Time Of HALT Command
OPIIPLTS - IPL Time
With MVS5, the data for the 'IPL WLM' event is obtained
from the SMF type 90 subtype 10 (System Status) record.
EVENT='IPL WLM'
OPINM1 - Active Service Policy name
OPINM2 - Userid of administrator who activated policy
OPINM3 - Name of the system where initiation occurred
OPINM4 - Installed Service Definition name
OPINM5 - Userid of installing administrator
OPINM6 - Name of the system where installed
WLMPOLTS - Service Policy Activation Time Stamp
WLMSDFTS - Service Definition Installation Time Stamp
The data for the 'IPL SRM' event is obtained from the SMF
type 90 subtype 10 (System Status) record.
EVENT='IPL SRM'
ENDTS - Time Of IPL Command
OPIIPLTS - IPL Time (TOD)
OPINM1 - IPS Parmlib Member Name Used
OPINM2 - OPT Parmlib Member Name Used
OPINM3 - ICS Parmlib Member Name Used
The data for the 'SET OPT' event is obtained from the SMF
type 90 subtype 11 (System Status) record.
EVENT='SET OPT'
ENDTS - Time Of SET Command
OPIEDGTS - Time Of SET Command (GMT)
OPINM1 - Old OPT Parmlib Member Name
OPINM2 - New OPT Parmlib Member Name
The data for the 'SET ICS' event is obtained from the SMF
type 90 subtype 12 (System Status) record.
EVENT='SET ICS'
ENDTS - Time Of SET Command
OPIEDGTS - Time Of SET Command (GMT)
OPINM1 - Old ICS Parmlib Member Name
OPINM2 - New ICS Parmlib Member Name
The data for the 'SET MPF' event is obtained from the SMF
type 90 subtype 14 (System Status) record.
EVENT='SET MPF'
ENDTS - Time Of SET Command
OPIEDGTS - Time Of SET Command (GMT)
OPINM1 - Old MPF Parmlib Member Name
OPINM2 - New MPF Parmlib Member Name for Color
OPINM3 - Old MPF Parmlib Member Name for Color
OPINM4 - New MPF Parmlib Member Name for Command
OPINM5 - Old MPF Parmlib Member Name for Command
The data for the 'SET DAE' event is obtained from the SMF
type 90 subtype 16 (System Status) record.
EVENT='SET DAE'
ENDTS - Time Of SET Command
OPIEDGTS - Time Of SET Command (GMT)
OPINM1 - Old Parmlib Member Name
OPINM2 - New Parmlib Member Name
The data for the 'SET PFK' event is obtained from the SMF
type 90 subtype 17 (System Status) record.
EVENT='SET PFK'
ENDTS - Time Of SET Command
OPIEDGTS - Time Of SET Command (GMT)
OPINM1 - Old PFK Parmlib Member Name
OPINM2 - New PFK Parmlib Member Name
The data for the 'SET GRSRNL' event is obtained from the
SMF type 90 subtype 18 (System Status) record.
EVENT='SET GRSRNL'
ENDTS - Time Of SET Command
OPIEDGTS - Time Of SET Command (GMT)
OPINM1-5 - Parmlib Member Names (GRSRNLxx)
The data for the 'INSTALL SDEF' event is obtained from
the SMF type 90 subtype 23 (System Status) record.
EVENT='INSTALL SDEF'
OPINM1 - Service Definition Name
OPINM2 - Userid of installing administrator
OPINM3 - Name of the system where installed
WLMSDFTS - Service Definition Installation Time Stamp
The data for the 'ACT SERVPOL' event is obtained from the
SMF type 90 subtype 24 (System Status) record.
EVENT='ACT SERVPOL'
OPINM1 - Service Policy Name
OPINM2 - Userid who activated the service policy
OPINM3 - Name of system where activation occurred
OPINM4 - Name of Service Definition from which service
policy was extracted
WLMSDFTS - Service Definition Installation Time Stamp
WLMPOLTS - Service Policy Activation Time Stamp
The data for the 'Processor Capacity Change' event is
obtained from the SMF type 90 subtype 34 (Process
Capacity Change)
EVENT='CAPACITY CHANGE'
OPICAPER - Processor Capacity Data Collection Err
OPICCGTS - Time When Capacity Last Changed
OPICPADI - Processor Capacity Adjustment Indicator
OPICPAFA - Actual Physical CPU Adjustment Factor
OPICPAFN - Nominal Physical CPU Adjustment Factor
OPICPCGR - Processor Capacity Change Reason
OPICPUSF - CPU Adjustment Scaling Factor
OPICSUF - Current Service Unit Factor
OPISUERR - OPICSUF Error Indicator
OPIZOSRL - z/OS Release of SMF Records
2. At IPL, following is the normal sequence of SMF records:
1. IPL
2. I/O Configuration
3. Configuration
4. System Status
5. JES Start
6. Vary Offline
3. If the OPINM1 and OPINM2 variables are blank for the
'SWITCH SMF' event, a data lost condition occurred.
4. Multiple records may be generated for each 'SET SMF',
'IPL SMF', 'SETSMF', and 'SET SMF (RESTART)' events.
CA MICS creates an observation in the OPI file for each
subsystem contained in the System Status record that
creates these events.
5. A 'SET DATE' event is only created when a SET DATE
command is issued without the CLOCK parameter. If the
CLOCK parameter is present, or a SET RESET command is
issued, a 'SET TIME' event is created.
6. Consider using the System Incident standard report
available for this file. For more information, see
section 3.1.3.
7. For information about how this statement affects the
OPSOPI file. see the SMFOPS parameter's INCIDENTLIMIT
statement in section 7.3.1.17.