KILL

Use the KILL command to terminate a true subtask that is failed to complete or that is looping.

Syntax

Use this format for the KILL command:

KILL TCB address

Parameters

The KILL command takes this parameter:

address

Address of the subtask's TCB.

Example

------------------------ CA‑GSS/ISERVE Control Panel --------- ROW 1 TO 1 OF 1 ==> kill tcb 6e5a10 => PAGE Target node: * ssid: * Host node: B1MAIN ssid ISRV ============================================================================== DETACH issued against 006E5A10

Other Responses

TCB specification not hexadecimal address

The specified address is not a valid hexadecimal value.

Invalid target specified

The string TCB did not follow the KILL command.

Usage Notes