Previous Topic: DISPLAY ENQUEUES

Next Topic: DISPLAY GLOBAL

DISPLAY FNTAB

Use the DISPLAY FNTAB command to display information about REXX functions that are loaded when CA‑GSS is initialized.

Syntax

Use this format for the DISPLAY FNTAB command:

Display FNTab [{External} [[+|-] {Class|Name} [[+|-] {Class|Name}]]
               {Internal}
               {Builtin}
               {All}

Parameters

The DISPLAY FNTAB command takes these parameters.

External

Lists only external functions (ones defined in the initialization parameters). This is the default.

Internal

Lists only internal (CA‑GSS extended) functions, which set the RC special variable.

Builtin

Lists only built-in functions, which are included as part of the language definition.

All

Lists all functions.

+

Sorts in ascending order. This is the default.

-

Sorts in descending order.

Class

Sorts by function class (external, internal, or built-in).

Name

Sorts by function name.

Usage Notes

Example

----------------------- CA‑GSS/ISERVE Control Panel ------ ROW 1 TO 19 OF 170 ==> display fntab all -class +name => PAGE Target node: * ssid: * Host node: B1EWF ssid EWF ============================================================================== Class Name Avail Module Type Address Length Rent AMODE -------- ---------- ----- -------- ----- -------- -------- ---- ----- Internal $CALLX Yes ***INT SYNC Internal $TIME Yes ***INT SYNC Internal ALIGN Yes ***INT SYNC Internal ALLOC Yes ***INT SYNC Internal BATCHR Yes ***INT SYNC Internal BOOLWORD Yes ***INT SYNC Internal CALC Yes ***INT SYNC Internal CASE Yes ***INT SYNC External ALERT SRVALERT SYNC 85DB9330 00001558 Yes 31 External SRVCALL Yes SRVCALL ASYNC 85DB1C38 000013C8 Yes 31

Fields in the Example

Class

Function's class, as follows:

Builtin

Function that is considered part of the language specification.

External

Processed by external load module specified in initialization parameters.

Internal

CA‑GSS extended function.

Name

Name of the function, as coded in IMODs.

Avail

Indicates whether or not the function is currently available for use by IMODs.

Module

Name of the load module that will be used to process the function.

Type

How the function executes, as follows:

ASYNC

Executes as a subtask.

SYNC

Executes under the main ISERVE task.

Address

Address in memory (hexadecimal) where the load module resides, if applicable.

Length

Length of the load module (hexadecimal) in memory, if applicable.

Rent

Indicates whether or not the load module is re-entrant, if applicable.

AMODE