Modify RACF or the RACF-Compatible Product

The product for which you are installing CAISSF has product‑specific classnames that need to be installed into RACF or the RACF‑compatible product. You should refer to your product‑specific documentation for information on the required classnames. The product classnames must be added to the RACF class descriptor table, ICHRRCDE, and to the RACF SAF router table, ICHRFRTB.

The following examples display what you need to code. The examples use classname CACMD. These are only examples. The product that is using CAISSF may not require this classname.

Note: Control statements can be continued on the next line when a dash (-) is placed at the end of the line to be continued.

Example 1: Class Descriptor Table Entry for CACMD

CACMD   ICHERCDE   CLASS=CA@MD,         -
                  {GROUP=DFTGRP,}       -
                   MAXLNTH=8,           -
                   FIRST=ALPHANUM,    -
                   OTHER=ANY,         -
                   OPER=NO,          -
                   DFTUACC=NONE,      -
                   ID=CLASS_NUMBER,       -
                   POSIT=19-255                    

Example 2: SAF Router Table Entry for CACMD

CACMD   ICHRFRTB   CLASS=CA@MD,  -
                   ACTION=RACF