Previous Topic: Initialization Routines

Next Topic: Auto Commands

Initialization Data Sets

You can direct CAIRIM to a specific data set for loading the initialization routine by specifying the LOADLIB parameter. The data set must be APF authorized. The LOADLIB parameter causes TASKLIB for the routine to switch to that data set.

If LOADLIB is used, the initialization routine and the associated CAIRIM program modules must be either in the LINKLST or in the data set specified by the LOADLIB parameter. If they are only in a CAIRIM STEPLIB, an S806 abend will occur.