If CAS9INIT finds no active security product (for example, when CAIRIM is run before the security product becomes active), the following messages are issued to the system console, prompting the operator to identify the security product:
CAS9075I - SERVICE(CA-RIM/BASE ) VERS(1200) GENLVL(0808AW000)
CAS9115I ‑ INPUT: *
CAS9115I ‑ INPUT: PRODUCT(CAIRIM) VERSION(CAS9) INIT(CAS9INIT)
CAS9025A ‑ NO SECURITY SYSTEM AVAILABLE
00 CAS9026A ‑ REPLY WITH SECURITY SYSTEM,"ACF2","TSS","RACF" OR
"N" TO CANCEL
If the reply identifies the security product, CAS9INIT continues to initialize CAISSF.
If the reply is N, the following message is issued and CAS9INIT fails to initialize CAISSF:
CAS9021E ENVIRONMENT ERROR DETECTED. UNABLE TO ADD CAISSF ROUTINES
You can bypass the operator prompt by adding the following parameter statement in the CAIRIM parmlib member, CAW0OPTN(CARIMPRM):
PRODUCT(CAIRIM) VERSION(CAS9) INIT(CAS9INIT) PARM(SSF(value))
Indicates one of ACF2, TSS, or RACF.