Technical Information › Program Properties Table › MVS/ESA and the PPT
MVS/ESA and the PPT
The system builds the PPT by merging the IEFSDPPT member of SYS1.LINKLIB with the SCHEDxx members that were specified in IEASYSxx according to the following rules:
- If an entry in the SCHEDxx member also appears in SYS1.LINKLIB (the IBM default PPT), the PPT entry from the SCHEDxx member overlays the IBM entry and sets the IBM ENTRY field to NO.
- If an entry is found in the SCHEDxx member of the logical Parmlib that is not in the PPT, the system adds the entry to the PPT at the first available spot.
- If duplicates are found in the non‑IBM PPT entries, the first of the duplicate entries is used. The system ignores the second entry. CA Auditor displays all entries in IEFSDPPT and the contents of all SCHEDxx members in the logical Parmlib.
CA Auditor displays all PPT entries and all SCHEDxx members specified in the logical Parmlib on the PPT Analysis Display (3.6).